Product overview
- Part Number
- MAX808LCSA+
- Manufacturer
- Maxim Integrated
- Product Category
- Supervisory Circuits
- Description
- Supervisory Circuits 8-Pin uP Supervisory Circuits with +/-1.5% Reset Accuracy
Documents & Media
- Datasheets
- MAX808LCSA+
Product Attributes
- Battery Backup Switching :
- Backup
- Manual Reset :
- No Manual Reset
- Maximum Operating Temperature :
- + 70 C
- Minimum Operating Temperature :
- 0 C
- Mounting Style :
- SMD/SMT
- Number of Inputs Monitored :
- 1 Input
- Output Type :
- Active Low, Push-Pull
- Package / Case :
- SOIC-8
- Packaging :
- Tube
- Reset Delay Time :
- 200 ms
- Series :
- MAX808L
- Supply Voltage - Max :
- 5.5 V
- Threshold Voltage :
- 4.675 V
- Type :
- Voltage Supervisory
- Watchdog Timers :
- No Watchdog
Description
Supervisory Circuits 8-Pin uP Supervisory Circuits with +/-1.5% Reset Accuracy
Price & Procurement
Associated Product
You May Also Be Interested In
Part | Manufacturer | Stock | Description |
---|---|---|---|
CT6 | Tektronix | 3 | Test Probes CT6 PROBE; CURRENT PROBE HIGH FREQ/SMALL GEOMETRY - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD |
TCP305A | Tektronix | 4 | Test Probes Probe AC/DC Current; 50Amp DC DC-50MHZ Certificate of Traceable Calibration Standard |
TRCP3000 | Tektronix | 1 | Test Probes Current Probe: 16 MHz 500 mA to 3000 A AC-Only BNC Interface |
P6022 | Tektronix | 3 | Test Probes Current Probe: 120 MHz 1 mA to 3 A AC BNC |
ZD500 | Teledyne LeCroy | 1 | Test Probes 500MHZ 1.0 PF ACTV DIFF PRB +-9V |
P6245 | Tektronix | 1 | Test Probes PROBE FET ACT; >1.5GHZ 10X <1PF TDS SERIES - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD |
ZD1000 | Teledyne LeCroy | 1 | Test Probes 1GHZ 1.0 PF ACTV DIFF PRB +-9V |
CP031 | Teledyne LeCroy | 1 | Test Probes 30A 100MHZ CUR PRB |
CP500 | Teledyne LeCroy | 2 | Test Probes 500A DC/AC CUR PRB 2MHZ |
ZS4000 | Teledyne LeCroy | 2 | Test Probes 4.0 GHz, 0.6 pF, 1 MOhm Active Voltage Probe |
N2751A | Keysight Technologies | 1 | Test Probes DIFFERENTIAL PROBE 3.5 GHz |
TCP404XL | Tektronix | 1 | Test Probes PROBE; AC/DC CURRENT DC-2MHZ 500A DC 750A DC DERATED WITH DUTY CYCLE CERTIFICATE OF TRACEABLE CALIBRATION STANDARD |
TAP2500 | Tektronix | 1 | Test Probes Active Probe: 2.5 GHz 10X Single-ended TekVPI |
CP150-6M | Teledyne LeCroy | 1 | Test Probes 150 A 10MHz CURRENT PROBE |
MS-250 | Teledyne LeCroy | 1 | Test Probes Mixed Signal Option 250 MHz,18 Ch,1 GS/s |